Dome Engineering Group

Building Envelope Consultant
As a certified building envelope consultant, we provide our knowledge, training, experience, and understanding of proper design and construction practices as related to your building envelope, including roofs, exterior walls, windows and doors.
Roofs
1 / Qualifications
National Claims Institute Certified Commercial Low Slope Roof Inspector
2 / Types of roofs
Types of roofs include Metal, Tile, Single Ply (PVC/TPO), Modified Bituminous, Fluid Applied
3 / Report to include:
-
Roof Membrane Condition
-
Roof Deck Moisture Survey and Leak Detection Report
-
In‐place roof system materials, condition, and deficiencies.
-
Installation errors, mechanical damages, other damages.
-
Identification of areas of wet roofing materials below the surface covering.
-
Identification of potential sources of water entry into the roof system and/or building envelope.
-
Testing Equipment – Tramex Deck Scanner, Roof/Wall Scanner, Tramex CMEX moisture probe meter, drone infrared thermal imaging
-
Testing according to ASTM D7954 methods
-
-
Roof Wind Uplift Testing – TAS 124
-
Roof Coring – Determine roof composite
-
HVAC roof unit strap down code requirement inspection
-
Roof Component Thermal Imaging for
Exterior Walls
1 / Construction
Includes masonry, concrete, metal studs, wood
2 / Wall covering
Includes stucco, EIFS, direct applied, siding
3 / Report to include:
-
Substrate Testing
-
Perform sounding testing to determine if wall is sound with no substrate damage
-
-
Dry Coating Thickness Milage Testing
-
To determine if coating thickness exceeds allowable thickness for complete removal
-
-
Coating Pin Hole Testing
-
Examine the existing coating for pin holes to determine if existing coating is providing a waterproofing shield
-
-
Coating Adhesion Testing
-
Determines if poor substrate cleaning exist to prevent the coating from bonding to the substrate surface
-
Determine if proper surface profile was created to provide good coating bonding
-
Determine if inappropriate wetting of coating on the substrate exist
-
Check for insufficient crosslinking/uncured coating/over-cured of coating to existing coatings or substrate
-
-
Coating Water Absorption Resistance Testing
-
Determine if existing coating is providing a waterproofing membrane
-
-
Coating Pre-Wash Testing for Contaminants and Proper PH
-
New coating projects testing to ensure wall contaminants have been removed
-
Ensure existing coating PH meets manufacturer's requirements prior to application of additional coating
-
-
Sealant Inspection & Testing
-
All perimeter wall sealants are inspected to evaluate the performance of the sealant and to determine the effects of aging and weathering
-
Sealant pull test are performed to determine bonding for old and new applications
-
Doors & Windows
1 / Report to include:
-
Glass Fracture Inspections
-
Glass pane is inspected for breakage and/or delamination
-
-
Glass Glazing Inspection
-
Identifying defective glazing such as cracks, separation, and adherence that lead to water and air leaks
-
Identify scratches from wind borne debris
-
-
Frame Inspection
-
Inspect frames for damage or seam separation
-
Inspect frames for torque/warpage
-
-
Sliding Door Closure Testing
-
Test sliding door for proper lockage per manufacturer's requirements
-
-
Water/Air Infiltration Testing
-
Perform ASTM water test for leakage
-
Perform ASTM air test for leakage
-
Perform smoke testing for air infiltration
-
-
Sealant Testing
-
Perform ASTM testing for insulated glass
-